Multi-tech-systems MT5634ZPX Bedienungsanleitung Seite 38

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 88
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 37
MT5634ZPX
38
Owners Manual
Command: O Return Online to Data Mode
Values: 0, 1, 3
Default: None
Description: O0 Exit online command mode and return to data mode.
O1 Issue a retrain and return to online data mode.
O3 Issue a rate renegotiation and return to data mode.
Command: Q
n
Result Codes Enable/Disable
Values:
n
= 0 or 1
Default: 0
Description: Q0 Enable result codes.
Q1 Disable result codes.
Command: S
r
=
n
Set Register Value
Values:
r
= S-register number;
n
varies
Default: None
Description: Set value of register S
r
to value of
n
, where
n
is
entered in decimal format.
Command: S
r
? Read Register Value
Values:
r
= S-register number
Default: None
Description: Read value of register
S
r
and display value in 3-digit
decimal form.
Command: V
n
Result Code Format
Values:
n
= 0 or 1
Default: 1
Description: V0 Displays result codes as digits (terse response).
V1 Displays result codes as words (verbose response).
Command: X
n
Result Code Selection
Values:
n
= 0–7
Default: 4
Description: X0 Basic result codes (
e.g., CONNECT
); does not look
for dial tone or busy signal.
X1 Extended result codes (
CONNECT 56000 V42bis,
CONNECT 33600 V42bis
, etc.); does not look for dial
tone or busy signal.
X2 Extended result codes with
NO DIALTONE
; does not
look for busy signal.
Seitenansicht 37
1 2 ... 33 34 35 36 37 38 39 40 41 42 43 ... 87 88

Kommentare zu diesen Handbüchern

Keine Kommentare