Chapter 4 – Command Line Interface (CLI)
Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) 57
SNTP Client Commands – Setup
SNTP Client Commands
Command Syntax set sntp client <enable/disable>
Description
Starts the SNTP Client to contact the configured server on UDP port 123
and set the local time.
Default Value
Disable
Success
OK
Error 1. Too few arguments
“Usage: set sntp-client <enable/disable>
Type set sntp-client ? for more information”
Command Syntax set sntp-client ntp-server-name <ip-address>
Description
Sets the NTP server IP address to which the SNTP Client has to contact to
update the time.
Default Value
0.0.0.0
Success
OK
Error 1. Invalid arguments
"error: Invalid IP address"
Type set sntp-client ? for more information”
2. Too few arguments
“Usage: set sntp-client ntp-server-name <ip-address>
Type set sntp-client ntp-server-name ? for more information”
Command Syntax set sntp-client time-zone <string (0-3)>
Description
Sets the time zone.
Default Value
UTC
Success
OK
Error 1. Invalid arguments
"error: Invalid Time Zone"
2. Too few arguments
“Usage: set sntp-client time-zone <string (0-3)>
Type set sntp-client time-zone ? for more information”
Command Syntax set sntp-client time-zone-offset <+/-hh:mm>
where
hh = 00 to 23
mm = 00 to 59
Description
Sets the offset time from UTC.
Default Value
+00:00
Success
OK
Error 1. Invalid arguments
"error: Invalid Offset"
2. Too few arguments
“Usage: set sntp-client time-zone-offset <+/-hh:mm>
Type set sntp-client time-zone-offset ? for more information”