Multi-tech-systems MTS2SA-T Bedienungsanleitung Seite 172

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 181
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 171
Appendix A – Flash Upgrade
Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) 172
Prerequisite 2 – Serial Port Configuration
The default serial port parameters should be:
Data length – 8 bits
Parity – None
Stop bits – 1
Baud-rate of the serial port to which the MultiConnect Adapter is connected should be set
to 115200 bps for proper operation.
Prerequisite 3 – Enabling TFTP Server
Enable TFTP server on MultiConnect Adapter by issuing the following command:
# set ip tftp enable
OK
Serial Flash Upgrade Scenario
Following steps explain the procedure to upgrade a flash using the serial COM port (serial flash upgrade).
Connect the MultiConnect Adapter to a PC COM Port.
Open an application through which we can access the serial device(e.g., Meterm, zoc,
hyperterm).
Reboot the MultiConnect Adapter.
Wait for the boot message and prompt “press d to download” to appear.
Press d when prompted.
Select the XMODEM Protocol from the Terminal application.
Choose a file (MTXCSEM-TFTP-…) file to be uploaded.
Perform a file upload.
The MultiConnect Adapter reboots and will be up after a few seconds (10-15 secs).
The MultiConnect Adapter reboots after it has been successfully upgraded.
Seitenansicht 171
1 2 ... 167 168 169 170 171 172 173 174 175 176 177 ... 180 181

Kommentare zu diesen Handbüchern

Keine Kommentare