Register Unit Range Default Description
S37
decimal 0–19 0 S37 sets the maximum V.34 "up-
stream" speed that the modem
attempts to connect.
0 = maximum negotiated modem
speed
1 = reserved
2 = 1200/75 bps
3 = 300 bps
4 = reserved
5 = 1200 bps
6 = 2400 bps
7 = 4800 bps
8 = 7200 bps
9 = 9600 bps
10 = 12000 bps
11 = 14400 bps
12 = 16800 bps
13 = 19200 bps
14 = 21600 bps
15 = 24000 bps
16 = 26400 bps
17 = 28800 bps
18 = 31200 bps
19 = 33600 bps
S38
decimal 0–14 1 Sets the maximum 56K "down-
stream" speed that the modem
attempts to connect.
0 = 56K Disabled
1 = 56K Enabled with automatic
speed selectionmaximum negoti-
ated modem speed enabled
2 = 32000 bps
3 = 34000 bps
4 = 36000
5 = 38000 bps
6 = 40000 bps
7 = 42000 bps
8 = 44000 bps
9 = 46000 bps
10 = 48000 bps
11 = 50000 bps
12 = 52000 bps
13 = 54000 bps
14 = 56000 bps