Chapter 4 - Commands
S4
Line Feed Character
Unit: ASCII Character
Range: 0-127
Default: 10
Description: Defines the character recognized as LINE FEED.
S5
Backspace Character
Unit: ASCII Character
Range: 0-127
Default: 8
Description: Defines the character recognized as BACKSPACE.
S6
Wait Time for Dial Tone
Unit: 1 second
Range: 2-255, 4-255**
Default: 2, 4**
Description: Sets the time the modem waits after the RETURN key is
pressed before executing a dial command.
S7
Time for Carrier (Abort Timer)
Unit: 1 second
Range: 1-255, 1-45*
Default: 45
Description: Defines the Abort Timer (lack of carrier) delay time.
S8
Pause Time for Comma
Unit: 1 second
Range: 0-255, 4-255**
Default: 2, 4**
Description: Sets the length of the pause caused by a comma inserted
in a dialing commarnational and DOC units
S9
Carrier Detect Response Time
Unit: 100 mSec.
Range: 1-255
Default: 6
Description: Sets the time delay for when the modem first detects a
valid incoming carrier signal and when the modem turns on
its Carrier Detect circuit.