MT2834ZPX Owner's Manual
S8
Pause Time for Comma
Unit: 1 second
Range: 0-255, 4-255**
Default: 2, 4**
Description: Sets the length of the pause caused by a comma inserted in a
dialing command.
S9
Carrier Detect Response Time
Unit: 100 mSec.
Range: 1-255
Default: 6
Description: Sets the time delay for when the modem first detects a valid
incoming carrier signal and when the modem turns on its Carrier
Detect circuit.
S10
Carrier Loss Disconnect Delay Time
Unit: 100 mSec.
Range: 0-255
Default: 7
Description: Sets the time a carrier signal must be lost before the modem
disconnects.
S11
Tone Dialing: Tone Spacing and Duration
Unit: 1 mSec.
Range: 1-255, 80-255*
Default: 70, 80*
Description: Sets the time duration of spacing between tone in tone-dialing.
* Value for International and DOC units
** Value for International Units only